+86-18930647859         sales@jush-pump.com
You are here: Home » Products » Centrifugal Pump » Self Priming Centrifugal Pump » ZW Type Stainless Steel Self-priming Water Pump with Insulation Jacket

ZW Type Stainless Steel Self-priming Water Pump with Insulation Jacket

5 0 Reviews
The ZW series stainless steel self-priming pump is a device designed to handle liquids containing large solid particles and long fiber impurities. Its unique design and functionality enable it to effectively handle liquids containing particles. This type of pump integrates self-priming and non clogging sewage discharge, adopting an axial reflux form. Through the unique design of the pump body and impeller flow channel, it can suction and discharge large solid particles, long fibers, sediments, waste impurities, fecal treatment, and all engineering sewage without the need to install bottom valves and inlet water. The design of ZW stainless steel self-priming pump enables it to handle impurities in the medium with a total weight not exceeding 15% of the total weight of the medium. The maximum particle diameter can reach 60% of the pump diameter, and the fiber length can reach 5 times the diameter, thus meeting the needs of handling liquids containing particles.
Availability:
Quantity:

PDF Export

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

The ZW series stainless steel self-priming pump is a device designed to handle liquids containing large solid particles and long fiber impurities. Its unique design and functionality enable it to effectively handle liquids containing particles. This type of pump integrates self-priming and non clogging sewage discharge, adopting an axial reflux form. Through the unique design of the pump body and impeller flow channel, it can suction and discharge large solid particles, long fibers, sediments, waste impurities, fecal treatment, and all engineering sewage without the need to install bottom valves and inlet water. The design of ZW stainless steel self-priming pump enables it to handle impurities in the medium with a total weight not exceeding 15% of the total weight of the medium. The maximum particle diameter can reach 60% of the pump diameter, and the fiber length can reach 5 times the diameter, thus meeting the needs of handling liquids containing particles.

Stainless steel self-priming pump with insulation jacket

Feature:


The feature of ZW type stainless steel self-priming pump mainly include strong overcurrent capacity, high efficiency and energy saving, good self-priming performance, strong sewage discharge capacity, simple and compact structure, stable and reliable operation, wide application, and convenient automation control. 

Strong overcurrent capacity: The special impeller anti blocking design ensures high efficiency and no blockage of the pump, suitable for conveying polluted liquids containing fiber substances and suspended solid particles impurities.

  • Efficient and energy-saving: Adopting excellent hydraulic models, the efficiency is 3-5% higher than that of general self-priming pumps.

  • Good self-priming performance: The self-priming height is 1 meter higher than that of a typical self-priming pump, and the self-priming time is shorter.

  • Strong sewage discharge capacity: The impeller of the water pump is open, with strong sewage discharge capacity and is not easily blocked.

  • Simple and compact structure: As the submersible sewage pump operates underwater, it can be directly installed in the sewage tank with a small footprint.

  • Stable and reliable operation: The internal design of the pump is reasonable, the operation is smooth, the noise is low, the vibration is small, and it has good durability and reliability.

  • Widely applicable: Suitable for industrial wastewater and urban domestic sewage, it is also used as a drainage pump, pulp pump, filtration flushing condensation circulation pump, irrigation pump, etc. It is widely used in mining, construction sites, hospitals, hotels, sewage treatment and other occasions.

  • Convenient automation control: It can be combined with automation control equipment to achieve remote control and monitoring, improving work efficiency and safety.


Structural diagram of ZW stainless steel self-priming pump

Application Area


ZW stainless steel self-priming pumps are widely used in various fields, including but not limited to municipal sewage engineering, river pond aquaculture, sedimentation of waste minerals and impurities, light industry, papermaking, food, chemical, pharmaceutical, power, paddle materials and mixtures. ‌


ZW stainless steel self-priming pumps are widely used in various industrial and municipal fields due to their unique performance advantages. Specifically, its application areas include:


  • Industrial production: In industries such as chemical, petroleum, pharmaceutical, textile, etc., ZW self-priming pumps are widely used in the process of transporting various corrosive, flammable, explosive, high-temperature and high-pressure media.

  • Agricultural irrigation: In fields such as farmland irrigation and water conservancy engineering, ZW self-priming pumps can be used to extract water sources such as groundwater and river water for irrigation and drainage.

  • Municipal construction: In the fields of urban water supply, drainage, and sewage treatment, ZW self-priming pumps can be used to transport media such as clean water and sewage.

  • Shipbuilding industry: In the shipbuilding industry, ZW self-priming pumps can be used for ship bottom drainage, fire protection and other systems.


In addition, ZW stainless steel self-priming pump also has the characteristics of simple structure, good self-priming performance, strong sewage discharge capacity, high efficiency and energy saving, and easy maintenance, making it an efficient and economical solution suitable for various industrial and municipal fields


FAQ:


  1. Pump leakage: This is one of the common faults of self-priming pumps. Pump leakage may be caused by aging or damaged seals. The solution is to replace or repair the seal.

  2. Insufficient pump suction: The insufficient suction of a self-priming pump may be caused by blockages inside the pump body and pipeline. Clearing blockages or replacing pipelines can solve this problem.

  3. Difficulty starting the pump: Difficulty starting the pump may be caused by motor failure, power failure, or mechanical component damage. Repairing the motor or replacing damaged components can solve this problem.

  4. Unstable pump flow: Unstable flow of self-priming pumps may be caused by excessively long or narrow inlet pipelines, or uneven wear of pump impellers. Adjusting the pipeline or replacing the impeller can solve this problem.

  5. High pump noise: The high noise of self-priming pumps may be caused by wear of the pump shaft and bearings, as well as loose internal components of the pump. Replacing new bearings or tightening loose parts can solve this problem.

  6. When the pump is in a shutdown state, there is no water: The inability of the self-priming pump to maintain a water seal during shutdown may be due to water leakage in the inlet pipeline or loose door plugs. Checking the sealing condition of the pipeline or adjusting the door plug can solve this problem.


Related Questions


What is a self priming water pump?

What are the disadvantages of self priming pumps?
Is a self priming pump better?
Do you have to add water to a self-priming pump?




Previous: 
Next: 

OUR COMPANY

JUSH is a modern pump and valve enterprise integrating R&D, production, sales and service.

QUICK LINKS

PRODUCT CATEGORY

CONTACT US

 +86-18930647859          
 Room 402, Block B, Twin Building, Area 668, Xinzhuan Road, Shanghai, China
Leave a Message
Contact Us
Copyright ©️ 2023 Shanghai Jiushi Pump Manufacturing Co., Ltd. Technology by leadong.com Sitemap.