WQP Type stainless steel corrosion-resistant submersible sewage pump is a submersible pump specially designed for use in sewage systems, with strong corrosion resistance and excellent sewage discharge capacity. It is made of high-quality stainless steel material, which can effectively resist the erosion of various corrosive liquids and sewage environments. It is widely used in sewage treatment, urban drainage, industrial wastewater discharge and other places.
1.WQP Type Corrosion-resistant Submersible Sewage Pump Technical Parameters
Material | Stainless Steel/Cast Iron |
Model | WQP((Specific parameters may vary depending on the specific model)) |
Rated flow rate | 5~1500 m³/(Depends on the model and configuration of the pump) |
Rated head | 8~50 m(Depending on the pump model and configuration, the head range can be adjusted) |
Motor Power | 0.75~75 KW(The power may vary depending on the specific model and application requirements) |
Working temperature range | 0℃~90℃ |
The maximum particle passing through the diameter | 25~100 mm(The maximum particle passing capacity of the pump varies depending on the model and impeller type) |
Motor voltage | 380V |
Protection grade | IP68(Completely waterproof, suitable for diving operations) |
Working medium | Wastewater containing solid particles, industrial wastewater, acidic and alkaline liquids, domestic wastewater, chemical waste liquids, etc |
2.WQP Type Corrosion-resistant Submersible Sewage Pump Feature
High quality stainless steel material
The pump body and impeller of the WQP series submersible sewage pump are made of high-quality stainless steel material, which has extremely strong corrosion resistance. Common stainless steel materials include 304 stainless steel, 316 stainless steel, etc. These materials can resist acid and alkali corrosion, oxidation, and rust, ensuring long-term stable operation of the pump in harsh environments.
High temperature resistance and wear resistance
The high temperature resistance and wear resistance of WQP stainless steel submersible sewage pump enable it to work for a long time in high-temperature liquids and wastewater containing solid particles. Whether in industrial wastewater, sewage, chemical liquids, or other environments, it can maintain excellent performance and avoid failures caused by corrosion and wear.
Efficient pollutant discharge capacity
The design of this series of submersible pumps focuses on sewage discharge capacity, equipped with large flow and high head impellers, which can effectively discharge sewage containing solid debris, sediment or other suspended solids, prevent pump body blockage, and improve sewage discharge efficiency. Suitable for treating wastewater with sediment, fibers, and other impurities.
Automatic protection function
WQP stainless steel submersible sewage pumps are usually equipped with various protection functions, such as overload protection, overheating protection, leakage protection, etc., to ensure that the pump will not be damaged due to abnormal conditions during operation, thereby extending its service life.
Low energy design
This series of sewage pumps adopts efficient motors and optimized hydraulic design, which can achieve high drainage efficiency with low power consumption, reduce energy consumption, and lower operating costs.
Diving operation, low noise
The WQP submersible sewage pump is designed as a fully enclosed submersible pump, with the pump body immersed in water for operation. This not only reduces noise pollution but also minimizes the impact of moisture in the air on the equipment, avoiding the hassle of traditional pumps requiring external water intake.
3.WQP Type Corrosion-resistant Submersible Sewage Pump Application Fields
sewage-treatment plant
WQP stainless steel submersible sewage pumps are widely used in the sewage transportation and discharge systems of sewage treatment plants. Due to its excellent corrosion resistance, it can work for a long time in wastewater containing corrosive substances.
industrial wastewater discharge
In some industrial production processes such as chemical, papermaking, and food industries, large amounts of industrial wastewater are often generated. WQP stainless steel submersible sewage pumps can efficiently treat these wastewater and ensure rapid discharge and treatment of the wastewater.
Municipal drainage system
For urban drainage and sewage systems, WQP submersible sewage pumps have important application value in subway construction, rainwater discharge, flood discharge and other projects. It can cope with harsh environments and ensure smooth drainage systems.
Agriculture and animal husbandry
In agricultural irrigation and animal husbandry, WQP stainless steel submersible sewage pumps can be used to treat large amounts of wastewater containing sewage or organic matter, ensuring water quality compliance and safe operation of facilities.
Construction site drainage
On construction sites, there is often water accumulation or construction sewage. WQP submersible sewage pumps can efficiently discharge sewage containing sediment and wastewater, ensuring the cleanliness of the construction site.
4.Scope of application and operating environment
Medium temperature: WQP stainless steel submersible sewage pump is suitable for operation within the range of 0 ℃ to 40 ℃. If higher temperature treatment is required under special working conditions, high-temperature models can be chosen, which can usually withstand sewage temperatures ranging from 50 ℃ to 90 ℃.
Installation method: Submersible installation is usually used, and horizontal or vertical installation can also be selected. Diving can help reduce external wear and water flow resistance of the pump body.
Protection level: WQP series pumps generally have an IP68 protection level, suitable for long-term underwater operation, and will not malfunction due to water immersion or sediment blockage.
5.Installation and maintenance
5.1. Installation requirements
WQP stainless steel submersible sewage pumps are usually installed in a submersible manner and work directly immersed in sewage. During installation, it is necessary to ensure the stability of the pump body position and prevent the tilting of the pump body from affecting its working efficiency. At the same time, the connection between the pump body and the cable should be firm to avoid loose or leaking cables.
5.2. Regular inspection and maintenance
Check the impeller and pump body: Regularly inspect the impeller and pump body for wear and corrosion. If necessary, clean the dirt and impurities on the impeller to ensure smooth operation.
Check the motor: Regularly check the operation of the motor to ensure that it is not overheated or overloaded. If there is any abnormal sound or high temperature, the machine should be stopped for inspection in a timely manner.
Replacing seals: The seals of the pump are critical components to prevent water leakage and require regular inspection and replacement of worn seals.
Clean the pump body and pipeline: Keep the pump body and pipeline clean to avoid the accumulation of dirt, which may affect the discharge efficiency of the pump.
5.3. Precautions for use
Avoid idling: The WQP submersible sewage pump needs to operate in liquid to avoid idling, which can cause motor damage.
Avoid severe vibration: During pump operation, it is necessary to avoid severe vibration and maintain a stable state to avoid unnecessary wear on the pump body and motor.
Reasonable selection of pump model: Choose the appropriate model of WQP submersible sewage pump based on the discharge volume, properties of the discharged liquid, and environmental characteristics to ensure that the pump's working load matches its design capacity.
6.WQP Type Corrosion-resistant Submersible Sewage Pump Performance Parameter
Model | Rate Flow (m³/h) | Rate Head(m) | Power (kW) | Maximum particle passing diameter(mm) | Working voltage(V) | Protection grade | Applicable Medium |
WQP10-30 | 10 | 30 | 1.1 | 35 | 380V | IP68 | Sewage, mildly corrosive liquids |
WQP20-25 | 20 | 25 | 2.2 | 40 | 380V | IP68 | Wastewater and liquids containing impurities |
WQP30-20 | 30 | 20 | 3.0 | 50 | 380V | IP68 | Wastewater, liquid containing solid particles |
WQP50-20 | 50 | 25 | 5.5 | 50 | 380V | IP68 | Wastewater and liquids containing large impurities |
WQP75-20 | 75 | 20 | 7.5 | 60 | 380V | IP68 | Urban drainage and industrial wastewater |
WQP100-15 | 100 | 15 | 11 | 80 | 380V | IP68 | Sewage and industrial wastewater |
WQP150-10 | 150 | 10 | 15 | 100 | 380V | IP68 | Municipal drainage and farmland irrigation |
WQP200-12 | 200 | 12 | 18.5 | 100 | 380V | IP68 | Wastewater containing solid particles |
WQP300-8 | 300 | 8 | 22 | 120 | 380V | IP68 | Large industrial drainage system |
If you need a product catalog or quotation for a specific model, please let us know your specific requirements!
Sewage Pump Related Issues
1.How To Judge The Operating Status of The Sewage Pump
2.What Problems Will Be Encountered in Sewage Pump Maintenance
3.Self-priming Sewage Pump Selection
4.How Does A Sewage Pump Work?
5.What Should Be Noted for Daily Maintenance of Sewage Pumps?
6.What Problems Will Sewage Pumps Encounter During Use
7.Common Faults And Solutions of Submersible Sewage Pumps
8.How To Choose A Submersible Sewage Pump
9.How To Install Sewage Pump & Precautions?
10.Common Faults And Solutions of Sewage Pumps
11.Application And Maintenance of Sewage Pumps
12.What Problems Will Sewage Pumps Encounter During Use?
Related Search keywords:
Sewage Pump | Effluent Pump | Drainage Pump | Wastewater Pump | Sump Pump | Dirty Water Pump
WQP Type stainless steel corrosion-resistant submersible sewage pump is a submersible pump specially designed for use in sewage systems, with strong corrosion resistance and excellent sewage discharge capacity. It is made of high-quality stainless steel material, which can effectively resist the erosion of various corrosive liquids and sewage environments. It is widely used in sewage treatment, urban drainage, industrial wastewater discharge and other places.
1.WQP Type Corrosion-resistant Submersible Sewage Pump Technical Parameters
Material | Stainless Steel/Cast Iron |
Model | WQP((Specific parameters may vary depending on the specific model)) |
Rated flow rate | 5~1500 m³/(Depends on the model and configuration of the pump) |
Rated head | 8~50 m(Depending on the pump model and configuration, the head range can be adjusted) |
Motor Power | 0.75~75 KW(The power may vary depending on the specific model and application requirements) |
Working temperature range | 0℃~90℃ |
The maximum particle passing through the diameter | 25~100 mm(The maximum particle passing capacity of the pump varies depending on the model and impeller type) |
Motor voltage | 380V |
Protection grade | IP68(Completely waterproof, suitable for diving operations) |
Working medium | Wastewater containing solid particles, industrial wastewater, acidic and alkaline liquids, domestic wastewater, chemical waste liquids, etc |
2.WQP Type Corrosion-resistant Submersible Sewage Pump Feature
High quality stainless steel material
The pump body and impeller of the WQP series submersible sewage pump are made of high-quality stainless steel material, which has extremely strong corrosion resistance. Common stainless steel materials include 304 stainless steel, 316 stainless steel, etc. These materials can resist acid and alkali corrosion, oxidation, and rust, ensuring long-term stable operation of the pump in harsh environments.
High temperature resistance and wear resistance
The high temperature resistance and wear resistance of WQP stainless steel submersible sewage pump enable it to work for a long time in high-temperature liquids and wastewater containing solid particles. Whether in industrial wastewater, sewage, chemical liquids, or other environments, it can maintain excellent performance and avoid failures caused by corrosion and wear.
Efficient pollutant discharge capacity
The design of this series of submersible pumps focuses on sewage discharge capacity, equipped with large flow and high head impellers, which can effectively discharge sewage containing solid debris, sediment or other suspended solids, prevent pump body blockage, and improve sewage discharge efficiency. Suitable for treating wastewater with sediment, fibers, and other impurities.
Automatic protection function
WQP stainless steel submersible sewage pumps are usually equipped with various protection functions, such as overload protection, overheating protection, leakage protection, etc., to ensure that the pump will not be damaged due to abnormal conditions during operation, thereby extending its service life.
Low energy design
This series of sewage pumps adopts efficient motors and optimized hydraulic design, which can achieve high drainage efficiency with low power consumption, reduce energy consumption, and lower operating costs.
Diving operation, low noise
The WQP submersible sewage pump is designed as a fully enclosed submersible pump, with the pump body immersed in water for operation. This not only reduces noise pollution but also minimizes the impact of moisture in the air on the equipment, avoiding the hassle of traditional pumps requiring external water intake.
3.WQP Type Corrosion-resistant Submersible Sewage Pump Application Fields
sewage-treatment plant
WQP stainless steel submersible sewage pumps are widely used in the sewage transportation and discharge systems of sewage treatment plants. Due to its excellent corrosion resistance, it can work for a long time in wastewater containing corrosive substances.
industrial wastewater discharge
In some industrial production processes such as chemical, papermaking, and food industries, large amounts of industrial wastewater are often generated. WQP stainless steel submersible sewage pumps can efficiently treat these wastewater and ensure rapid discharge and treatment of the wastewater.
Municipal drainage system
For urban drainage and sewage systems, WQP submersible sewage pumps have important application value in subway construction, rainwater discharge, flood discharge and other projects. It can cope with harsh environments and ensure smooth drainage systems.
Agriculture and animal husbandry
In agricultural irrigation and animal husbandry, WQP stainless steel submersible sewage pumps can be used to treat large amounts of wastewater containing sewage or organic matter, ensuring water quality compliance and safe operation of facilities.
Construction site drainage
On construction sites, there is often water accumulation or construction sewage. WQP submersible sewage pumps can efficiently discharge sewage containing sediment and wastewater, ensuring the cleanliness of the construction site.
4.Scope of application and operating environment
Medium temperature: WQP stainless steel submersible sewage pump is suitable for operation within the range of 0 ℃ to 40 ℃. If higher temperature treatment is required under special working conditions, high-temperature models can be chosen, which can usually withstand sewage temperatures ranging from 50 ℃ to 90 ℃.
Installation method: Submersible installation is usually used, and horizontal or vertical installation can also be selected. Diving can help reduce external wear and water flow resistance of the pump body.
Protection level: WQP series pumps generally have an IP68 protection level, suitable for long-term underwater operation, and will not malfunction due to water immersion or sediment blockage.
5.Installation and maintenance
5.1. Installation requirements
WQP stainless steel submersible sewage pumps are usually installed in a submersible manner and work directly immersed in sewage. During installation, it is necessary to ensure the stability of the pump body position and prevent the tilting of the pump body from affecting its working efficiency. At the same time, the connection between the pump body and the cable should be firm to avoid loose or leaking cables.
5.2. Regular inspection and maintenance
Check the impeller and pump body: Regularly inspect the impeller and pump body for wear and corrosion. If necessary, clean the dirt and impurities on the impeller to ensure smooth operation.
Check the motor: Regularly check the operation of the motor to ensure that it is not overheated or overloaded. If there is any abnormal sound or high temperature, the machine should be stopped for inspection in a timely manner.
Replacing seals: The seals of the pump are critical components to prevent water leakage and require regular inspection and replacement of worn seals.
Clean the pump body and pipeline: Keep the pump body and pipeline clean to avoid the accumulation of dirt, which may affect the discharge efficiency of the pump.
5.3. Precautions for use
Avoid idling: The WQP submersible sewage pump needs to operate in liquid to avoid idling, which can cause motor damage.
Avoid severe vibration: During pump operation, it is necessary to avoid severe vibration and maintain a stable state to avoid unnecessary wear on the pump body and motor.
Reasonable selection of pump model: Choose the appropriate model of WQP submersible sewage pump based on the discharge volume, properties of the discharged liquid, and environmental characteristics to ensure that the pump's working load matches its design capacity.
6.WQP Type Corrosion-resistant Submersible Sewage Pump Performance Parameter
Model | Rate Flow (m³/h) | Rate Head(m) | Power (kW) | Maximum particle passing diameter(mm) | Working voltage(V) | Protection grade | Applicable Medium |
WQP10-30 | 10 | 30 | 1.1 | 35 | 380V | IP68 | Sewage, mildly corrosive liquids |
WQP20-25 | 20 | 25 | 2.2 | 40 | 380V | IP68 | Wastewater and liquids containing impurities |
WQP30-20 | 30 | 20 | 3.0 | 50 | 380V | IP68 | Wastewater, liquid containing solid particles |
WQP50-20 | 50 | 25 | 5.5 | 50 | 380V | IP68 | Wastewater and liquids containing large impurities |
WQP75-20 | 75 | 20 | 7.5 | 60 | 380V | IP68 | Urban drainage and industrial wastewater |
WQP100-15 | 100 | 15 | 11 | 80 | 380V | IP68 | Sewage and industrial wastewater |
WQP150-10 | 150 | 10 | 15 | 100 | 380V | IP68 | Municipal drainage and farmland irrigation |
WQP200-12 | 200 | 12 | 18.5 | 100 | 380V | IP68 | Wastewater containing solid particles |
WQP300-8 | 300 | 8 | 22 | 120 | 380V | IP68 | Large industrial drainage system |
If you need a product catalog or quotation for a specific model, please let us know your specific requirements!
Sewage Pump Related Issues
1.How To Judge The Operating Status of The Sewage Pump
2.What Problems Will Be Encountered in Sewage Pump Maintenance
3.Self-priming Sewage Pump Selection
4.How Does A Sewage Pump Work?
5.What Should Be Noted for Daily Maintenance of Sewage Pumps?
6.What Problems Will Sewage Pumps Encounter During Use
7.Common Faults And Solutions of Submersible Sewage Pumps
8.How To Choose A Submersible Sewage Pump
9.How To Install Sewage Pump & Precautions?
10.Common Faults And Solutions of Sewage Pumps
11.Application And Maintenance of Sewage Pumps
12.What Problems Will Sewage Pumps Encounter During Use?
Related Search keywords:
Sewage Pump | Effluent Pump | Drainage Pump | Wastewater Pump | Sump Pump | Dirty Water Pump